Operation, 5 capacity control device – MMD Equipment 185S-6C2 User Manual

Page 31

Advertising
background image

4.Operation

4-12

4.5 Capacity Control Device


Step Response

Start

When starting operation, purge solenoid valve SV1 opens.

And compressed air is sent to unloader chamber A and speed regulator

chamber B . The pressure in chamber A rises soon, and unloader

valve fully closes due to low pressure. Thus the load required for starting
is reduced.

Load operation

After the unit starts, it automatically performs unloaded operation and
then solenoid valve SV1 closes. As discharge pressure increases and

decreases, air flow from pressure regulator to the chamber A and

B increases and decreases. Thus, unloader valve position and engine

speed changes, and accordingly it regulates delivery air steplessly from

0 to 100 %

Suction port closing

unload operation

When air consumption is reduced, and the pressure exceeds the rated

one, speed regulator functions to lower the engine speed in proportion to

the pressure rise and, at the same time, to close unloader valve.

Under unloaded operation, the interior of compressor air-end becomes

vacuum and vacuum noise is caused. In order to prevent occurrence of

vacuum noise, it functions to open the vacuum relief valve, detecting the

secondary pressure of pressure regulator and thus it prevents high

vacuum state inside the compressor air end from being caused.

A100449E

Advertising