3.9.5

LOOP CIRCUIT ON/OFF

This command may be used to turn ON or OFF any of the 8 loop circuits without effecting the monitoring capability. This
command can be effective in disabling an input that has generated an alarm, in order to allow you to re-establish the "ARM"
mode without that input generating a new alarm.

COMMAND CODE:

04

COMMAND SYNTAX:

04 [Key Code] [Loop] [ON/OFF] #

READ BACK SYNTAX:

04 [Loop] #

WHERE:

Key Code = Reference current key code
Loop = 1 through 8
ON/OFF = Zero (0) or Non Zero (1-9)

EXAMPLE:

04 11 1 0 # = Turn off loop 1 so that it will not generate an alarm
04 11 1 1 # = Turn on loop 1 and allow it to generate an alarm

3.9.6

LOOP MONITOR ON/OFF COMMAND

Any of the 8 loops may be programmed to operate the relay or digital output for the purpose of monitoring the loop circuit's
input activity. Issuing a loop monitor ON command will enable any loop circuit that has been defined to operate either the
relay or digital output to do so (reference the programming section of this manual for more information on configuration of
the monitor function). This function will operate independent of the ARM/DISARM function, including, the turning loop
circuits off.

COMMAND CODE:

05

COMMAND SYNTAX:

05 [Key Code] <ON/OFF> #

READ BACK SYNTAX:

05 #

WHERE:

Key Code = reference current key code.
ON/OFF = Zero (0) or Non Zero (1-9)

EXAMPLE:

05 11 # = Toggle loop monitor function to opposite mode
05 11 0 # = Turn loop monitor function off

3.9.7

RESERVED FOR FUTURE USE

COMMAND CODE:

06

3.9.8

RESERVED FOR FUTURE USE

COMMAND CODE:

07

3.9.9

RESERVED FOR FUTURE USE

COMMAND CODE:

08