Pacific Research Solutions PET-820 User Manual
Page 32
Pacific Research
PET-820 User Manual
Page 31
4.5.28 SET DAY OF WEEK, RTC OPTION
If your PET-820 has included the Real Time Clock option, the day of week can be adjusted using this command:
COMMAND CODE:
39
PROGRAM SYNTAX:
39 [Data] #
READ BACK SYNTAX:
39#
WHERE:
Data = 1 through 7,
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
EXAMPLE:
39 3 # = Set the day for Tuesday
DEFAULT:
Current day
4.5.29 ALARM COMMUNICATION
This feature allows the user to define what type of communications will be used during the alarm condition. DTMF
communication should only be selected in applications that will communicate with the remote control panel.
COMMAND CODE:
40
PROGRAM SYNTAX:
40 [Data] #
READ BACK SYNTAX:
40 #
WHERE:
Data = 0 through 3,
0 = None
1 = DTMF
2 = Speech
3 = Modem
EXAMPLE:
40 2 # = Communicates using speech
DEFAULT:
2
4.5.30 PROGRAMMING AND CONTROL COMMUNICATION
This feature allows the user to define what type of communications will be used during the programming and control modes
of the system. DTMF communication should only be selected in applications that will communicate with the remote control
panel.
COMMAND CODE:
41
PROGRAM SYNTAX:
41 [Data] #
READ BACK SYNTAX:
41 #
WHERE:
Data = 0 through 3,
0 = None
1 = DTMF
2 = Speech
3 = Modem
EXAMPLE:
41 2 # = Communicates using speech
DEFAULT:
2
4.5.31 RADIO INTERFACE ENABLE
When this feature is selected it enables a protocol to allow the system to communicate via a two way radio. Reference the
installation section of this manual for more information on interfacing with a two way radio. In most applications where
telephone interface is desired this function should be disabled.
COMMAND CODE:
42
PROGRAM SYNTAX:
42 [Data] #
READ BACK SYNTAX:
42 #
WHERE:
Data = Zero (0) or Non Zero (1-9), 0 = Telephone interface
EXAMPLE:
42 0 # = Enables the telephone interface
DEFAULT:
0