PROGRAMMING TABLE

Command

Code

Programming Command Description

Command

Syntax

Factory

Setting

New

Setting

10

Set loop response time #1
40 Milliseconds to 10.2 Seconds, 001 = 40 mS

10 [DATA] #

001

40 mS

11

Set loop response time #2
40 Milliseconds to 10.2 Seconds, 025 = 1000 mS (1 Sec)

11 [DATA] #

025

1000 mS

12

Change PAC (Program Authorization Code)
1 to 6 Digits

12 [DATA] #

987654

13

Change Operate Key Code
1 to 6 Digits

13 [DATA] #

11

14

Change Password
1 to 6 Digits

14 [DATA] #

321

15

Change unit address
1 to 4 Digits

15 [DATA] #

0000

16

Set arm delay
000 to 255 Seconds

16 [DATA] #

015

Seconds

17

Set telephone dial delay after alarm
000 to 255 Seconds

17 [DATA] #

005

Seconds

18

Set alarm cutoff
000 to 255 Seconds

18 [DATA] #

030

Seconds

19

Set alarm delay
000 to 255 Seconds

19 [DATA] #

015

Seconds

20

Set password error counter
00 to 15 Errors, 00 = Disable counter

20 [DATA] #

02

Errors

21

Set communication dial attempts
00 to 15 Attempts, 00 = No communication attempts

21 [DATA] #

08

Attempts

22

Set telephone number 1
1 to 32 Digits

22 [DATA] #

None

23

Set telephone number 2
1 to 32 Digits

23 [DATA] #

None

24

Select speech message buffer to update
Buffer address 00 through 15

24 [DATA] #

00

Buffer 0

25

Change speech message data
Word Address 00 through 15
Word 000 through 255

25 <WORD ADDRESS> [WORD] #

See Section

4.4.15

26

Select sign on message
Message buffer 00 through 15

26 [DATA] #

02

Buffer 2

27

Set ring counter for off hook
00 to 15 Rings
00=Disable counter or 15 rings with program switch on

27 [DATA] #

04

Rings

28

Select alarm message delay
Select 0 to 3, 0=None, 1=5 Sec., 2=15 Sec., 3=30 Sec.

28 [DATA] #

1

5 Seconds

29

Reserved for future use

Revised 10/13/92