EEPROM PROGRAMMING DATA TABLE

ADDRESS

DEFAULT DATA

DESCRIPTION

000

001

LOOP RESPONSE 1, 40 mS

001

025

LOOP RESPONSE 2, 1000mS (1 Second)

002
003
004

150 (98 HEX)
118 (76 HEX)
084 (54 HEX)

PROGRAM AUTHORIZATION CODE
987654 (STORED IN BCD)

005
006
007

050 (32 HEX)
031 (1F HEX)
255 (FF HEX)

PASSWORD 321 (STORED IN BCD)

008
009
010

017 (11 HEX)
255 (FF HEX)
255 (FF HEX)

KEY CODE 11 (STORED IN BCD)

011
012

000 (00 HEX)
000 (00 HEX)

THE PET's ADDRESS (ID)
0000 (STORED IN BCD)

013

162 (10100010B)

SYSTEM CONFIGURATION BYTE 1

014

000 (00000000B)

SYSTEM CONFIGURATION BYTE 2

015

067 (01000011B)

SYSTEM CONFIGURATION BYTE 3

016

130 (10000010B)

LOOP 1 DEFINITION, LOW BYTE

017

024 (18 HEX)

LOOP 1 DEFINITION, HIGH BYTE

018

130 (10000010B)

LOOP 2 DEFINITION, LOW BYTE

019

025 (19 HEX)

LOOP 2 DEFINITION, HIGH BYTE

020

130 (10000010B)

LOOP 3 DEFINITION, LOW BYTE

021

026 (1A HEX)

LOOP 3 DEFINITION, HIGH BYTE

022

130 (10000010B)

LOOP 4 DEFINITION, LOW BYTE

023

027 (1B HEX)

LOOP 4 DEFINITION, HIGH BYTE

024

130 (10000010B)

LOOP 5 DEFINITION, LOW BYTE

025

028 (1C HEX)

LOOP 5 DEFINITION, HIGH BYTE

026

130 (10000010B)

LOOP 6 DEFINITION, LOW BYTE

027

029 (1D HEX)

LOOP 6 DEFINITION, HIGH BYTE

028

130 (10000010B)

LOOP 7 DEFINITION, LOW BYTE

029

030 (1E HEX)

LOOP 7 DEFINITION, HIGH BYTE

030

130 (10000010B)

LOOP 8 DEFINITION, LOW BYTE

031

031 (1F HEX)

LOOP 8 DEFINITION, HIGH BYTE

032

015

ARM DELAY 15 SECONDS, 0-255 SECONDS

033

015

ALARM DELAY 15 SECONDS, 0-255 SECONDS

034

005

DIAL DELAY 5 SECONDS, 0-255 SECONDS

035

030

ALARM RELAY CUTOFF 30 MIN., 0=NO CUTOFF

036

066 (42 HEX)

RING COUNT, 0 = DISABLE DET. (HIGH NIBBLE)
PASSWORD ERROR COUNTER (LOW NIBBLE)

037

008

DIAL ATTEMPTS 8, 0 = DISABLE DIALER

038

255 (FF HEX)

MODEM CONFIGURATION

039-054

ALL 255 (FF HEX)

TELEPHONE NUMBER 1

055-070

ALL 255 (FF HEX)

TELEPHONE NUMBER 2

071-086

001, 050, 049, 201, 158, 186, 000, 000,
000, 000, 000, 000, 000, 000, 000, 000

SPEECH MESSAGE BUFFER #1
"DC POWER IS OFF"

087-102

001, 009, 014, 134, 240, 007, 000, 000,
000, 000, 000, 000, 000, 000, 000, 000

SPEECH MESSAGE BUFFER #2
"(009) FROM UNIT (007)"

103

000 (00 HEX)

END OF SPEECH BUFFER

104

006

SERIAL CONFIGURATION BYTE, 9600 BAUD

105

010

ALARM MESSAGE COUNT

106

255 (11111111B)

SYSTEM CONFIGURATION BYTE 4

107-127

ALL 255 (FF HEX)

UNUSED