Programming table – Pacific Research Solutions PET-820 User Manual
Page 63
Pacific Research
PET-820 User Manual
Page 62
PROGRAMMING TABLE
Command
Code
Programming Command Description
Command
Syntax
Factory
Setting
New
Setting
60
Reserved for future use
61
Reserved for future use
62 - 65
See OPERATE COMMAND TABLE
66
ADC OPTION: Reset analog high and low values
Select input 1 through 8
66 [INPUT] #
None
67
See OPERATE COMMAND TABLE
68
ANALOG SCALING: Enable sign for analog scaled
values
Select input 1 through 8, Non Zero = Enable
68 [INPUT]
[DATA] #
0
Enable
69
ANALOG SCALING: Change speech identifier for analog
scaled values
Select input 1 through 8
Word = 000 through 255, String 1 to 4 words together.
69 [INPUT]
[WORD]
<WORD>
<WORD>
<WORD> #
245
"Volts"
70
ADC OPTION: Set upper analog alarm limit
Select input 1 through 8, Sign = Zero (neg)/Non Zero(pos)
Data = 0000 through 4096, ADC value
70 [INPUT]
[SIGN] [DATA] #
+4096
Limit
disabled
71
ADC OPTION: Set lower analog alarm limit
Select input 1 through 8, Sign = Zero (neg)/Non Zero(pos)
Data = 0000 through 4096, ADC value
71 [INPUT]
[SIGN] [DATA] #
-4096
Limit
disabled
72
ADC OPTION: Set input integrate rate
Data = 1 through 8
72 [INPUT]
[DATA] #
4
Readings
73
ADC OPTION: Enable input to trigger alarm
Select input 1-8, Data = Zero (disable)/Non Zero (enable)
73 [INPUT]
[DATA] #
0
Disable
74
ADC OPTION: Enable input to trigger alarm relay output
Select input 1-8, Data = Zero (disable)/Non Zero (enable)
74 [INPUT]
[DATA] #
0
Disable
75
ADC OPTION: Telephone number access
Select 0 to 7
0=None 1=Number 1
2=Number 2 3=Number 1 and 2,
4=8 Number log 5=Number 1 and log
6=Number 2 and log 7=Number 1, 2 and log
75 [INPUT]
[DATA] #
1
None
76
ADC OPTION: Select analog alarm message
Select input 1-8, Data = 00-15 (message buffer)
76 [INPUT]
[DATA] #
00
Message
77
ADC OPTION: Select alarm delay for analog alarm
Select input 1-8, Data = Zero (no delay)/Non Zero (delay)
77 [INPUT]
[DATA] #
0
No delay
78
ADC OPTION: Select single/differential ended input
Data = Zero (single)/Non Zero (diff.)
78 [DATA] #
0
Single end
79
ADC OPTION: Set analog high / low range
Select input 1-8, Data = Zero (low)/Non Zero (high)
79 [DATA] #
1
High range
80
Initialization of speech data, RAM/RTC Option
80 #
None
81
System EEPROM Initialization, This command does not
require Password of Program Authorization Code
81 [SER. NO.] #
None
82
Change direct byte in EEPROM
Address and data require 3 digit values
82 [ADDRESS]
[DATA] #
N/A
83
Demonstrate all words in speech library
83 #
None
84
ADC OPTION: Initialization ADC
84 [SER. NO.] #
None
Revised 12/14/94