REMKO WKF 85 User Manual

Page 11

Advertising
background image

Series

WKF 180

WKF-compact

180

Max. power consumption

kW

4,5

Power factor A7/W35 (cosφ)

--

0,95

Fuse protection on-site (outdoor unit, delax-action)

A

3 x 16 A

Rated water flow (according to EN 14511, at ∆t 5 K)

m³/h

2,4

Pressure-loss at the condenser at nominal flow rate

bar

0,1

Pressure-loss external

kPa

80

Air-nominal flow rate outdoor module

m³/h

5400

Max. operating pressure, water

bar

3

Hydraulic connection, supply / return

Inches (mm)

1" (25,4)

Sound-power level in accordance with ISO 9614-2

dB(A)

54 / 42 / 36

Sound-pressure level, LpA (outdoor module)

3

dB(A)

42,4

Dimensions, indoor module (height/width/depth)

mm

500/800/500

1928/800/790

Dimensions, outdoor module (height/width/depth)

mm

1420 / 940 / 330

Enclosure class outdoor module

--

IP 24

Weight indoor module

kg

55

226

Weight outdoor module

kg

100

1)

COP = coefficient of performance or performance number according to EN 14511

2)

Contains greenhouse gas according to Kyoto protocol, GWP 1975

3)

Distance 5m, TÜV tested, A7/W55/58Hz, at full spherical propagation

Data provided without guarantee! We reserve the right to modify the dimensions and constructional design

as part of the ongoing technical-development process.

11

Advertising
This manual is related to the following products: