9 elektrical connection, 1 general notes, Elektrical connection 9.1 general notes – REMKO WKF 85 User Manual

Page 55: Elektrical connection

Advertising
background image

9

Elektrical connection

9.1

General notes

n

It is necessary to lay a power-supply cable

both to the outdoor unit and, separately, to the

indoor unit.

n

Power to the indoor unit may not be discon-

nected by the power company (frost protec-

tion).

n

All indoor modules require a single-phase

power supply at 230 V / 50 Hz.
The outdoor modules series WKF/WKF-com-

pact 85/120 require a single-phase power

supply at 230 V / 50 Hz and the outdoor mod-

ules series WKF/WKF-compact 180 require a

three-phase power supply at 400 V / 50 Hz.

n

The electrical connection between outdoor-

and indoor units is made using two-wire control

cable.

n

Where applicable, a separate three-phase

power supply 400 V / 50 Hz shall be provided

to the indoor unit for electric booster heating.

n

The Smart-Control needs to know whether a

power-company release- or off-period is in

effect. An electrically-isolated switch must be

installed for this purpose (an closed switch sig-

nifies power available, an open switch, off-

time).

n

In the chapter "Connection diagram, terminal

configuration" in this manual can be found a

connection schematic along with corre-

sponding circuit diagrams.

n

Special rates for heat pumps may be offered

by the power company (PSC).

n

Ask your local power company about the

details of any rates that might be available.

DANGER!

All electrical installation work must be done by

an electrician.

WARNING!

Always note the currently applicable VDE

guidelines and the notes in TAB 2007. The size

and type of the fuse are to be taken from the

technical data.

WARNING!

All cable sizes are to be selected according to

VDE 0100. Special attention should be given to

cable lengths, cable type and the kind of instal-

lation. The information in the connection dia-

gram and in the system overview are to be

seen as an acceptable installation possibility

only in a standard case!

NOTICE!

Make sure to connect the outdoor unit neutral

connector properly, otherwise the varistors on

the line-filter circuit board will be destroyed.

NOTICE!

The electrical connection for the units must be

made at a separate feedpoint with a residual

current device in accordance with local regula-

tions and should be laid out by an electrician.

Check all plugged and clamped terminals to

verify that they are seated correctly and make

permanent contact. Tighten as required.

55

Advertising
This manual is related to the following products: