5 heat pump service limits in monovalent mode, Heat pump service limits in monovalent mode, Vt [ ° c] [ ° c] at – REMKO WKF 85 User Manual

Page 15

Advertising
background image

2.5

Heat pump service limits in monovalent mode

-20°C; 22°C

-20°C; 40°C

-10; 50

35; 50

35°C; 22°C

15°C

20°C

25°C

30°C

35°C

40°C

45°C

50°C

55°C

-30°C

-20°C

-10°C

0°C

10°C

20°C

30°C

40°C

V

or

la

uft

em

pe

ra

tu

r [

°C

]

Außentemperatur [°C]

VT

[ °

C]

[ ° C]

AT

Fig. 6: Service limits and test points WKF/WKF-compact 85

AT: Outside temperature VT: Inlet temperature

Outdoor temperature [°C]

-20

-20

-10

20

35

35

Inlet temperature [°C]

22

40

50

50

50

22

-20°C; 22°C

-20°C; 43°C

-10; 55

35; 55

35°C; 22°C

15°C

20°C

25°C

30°C

35°C

40°C

45°C

50°C

55°C

60°C

-30°C

-20°C

-10°C

0°C

10°C

20°C

30°C

40°C

V

or

la

uft

em

pe

ra

tu

r [

°C

]

Außentemperatur [°C]

Einsatzgrenzen WKF 120

VT

[ °

C]

[ ° C]

AT

Fig. 7: Service limits and test points WKF/WKF-compact 120

AT: Outside temperature VT: Inlet temperature

Note: The left temperature value in the diagram refers to the supply-temperature heating water and the lower

refers the outdoor air temperature.

Outdoor temperature [°C]

-20

-20

-10

20

35

35

Inlet temperature [°C]

22

43

55

55

55

22

15

Advertising
This manual is related to the following products: