Space Ray PTS Series Single Stage User Manual

Page 47

Advertising
background image

Form 43343330

-46-

Aug 2012

Remove blockage.

Rest

art

troubleshooting.

Cont

act factory for

assist

ance.

No

Y

es

No

No

Y

es

Does the amber light

st

ay on p

ast 10

seconds?

No

Y

es

Check the micro

Amp

s at the FC-FC+

terminals of the

module is it greater

than 0.7

µA

with flame.

T

urn on the gas

valve?

Does LED on the

ignition module flash

three times?

Replace ignition

module.

Check flame sense

wire does it have

continuity?

No

Y

es

Check vent and fresh

air lengths, are they

within the maximum

permissible?

Cont

act factory for

assist

ance.

Replace flame sense

wire.

No

Y

es

Check air plate

st

amped p

art

numbers.

Are they

correct?

No

Y

es

Check turbulator

, are

the correct number of

lengths inst

alled?

Rep

air or replace

jumper check all wire

terminals.

Change number of

turbulators.

Adjust terminal

connection. Rest

art

troubleshooting.

No

Y

es

No

Y

es

Remove burner

casting and check

the orifice. Is it clean

and free from

blockage?

No

Y

es

Check the pressure

across the air switch

during hot running is

it higher than the

minimum required?

Check gas pipe

sizing, regulators and

system supply gas

pressures.

Adjust manifold

pressure. Rest

art

troubleshooting.

T

roubleshoot Ends

No

Y

es

Is the knob on the gas

valve turned to the

ON position?

No

Y

es

Through the

inspection window is

there a flame visible

during st

art up?

No

Y

es

Is the heater properly

grounded?

Correct grounding

problem.

No

Y

es

Check the terminal on

the flame sense

electrode, is it tight?

No

Y

es

Remove and inspect

flame sense

electrode. Is it clean

and the ceramic

int

act?

Rep

air or replace

flame sense

electrode.

Y

es

Check the gas supply

pressure with all the

heaters on. Does it

st

ay above the

minimum required?

No

No

Y

es

Check the air int

ake

and vent are there

any blockages?

No

Y

es

Is a cold air stopper

inst

alled in the fresh

air int

ake?

No

Y

es

Is the heater properly

grounded?

No

Y

es

No

Y

es

No

Y

es

No

Y

es

No

Y

es

Remove blower is the

wheel free from dirt

and dust?

Replace air switch

No

Y

es

Remove blower does

the wheel turn freely?

Replace blower

assembly

.

Replace air plate.

Cont

act factory for

assist

ance.

No

Y

es

Is the cold air stopper

inst

alled with the

hinge vertical?

Move cold air stopper

with the hinge in the

vertical position.

Rest

art

troubleshooting.

No

Y

es

Does the amber light

st

ay on until the

thermost

at turns of

f?

See next p

age for

troubleshooting

sequence.

No

Y

es

Replace ignition

module.

No

Y

es

Does LED on the

ignition module flash

once?

Y

es

Does LED on the

ignition module flash

three times?

Af

ter an initial step

opening is the

manifold gas

pressure correct?

Correct grounding

problem.

Remove blockage.

Rest

art

troubleshooting.

Clean blower wheel.

Rest

art

troubleshooting.

Cont

act factory for

assist

ance.

Check the micro

Amp

s at the FC-FC+

terminals of the

module is it greater

than 0.7

µA

with flame.

Check the terminal on

the flame sense

electrode, is it tight?

Check flame sense

wire does it have

continuity?

Replace flame sense

wire.

Adjust terminal

connection. Rest

art

troubleshooting.

Remove and inspect

flame sense

electrode. Is it clean

and the ceramic

int

act?

Rep

air or replace

flame sense

electrode.

Cont

act factory for

assist

ance.

Advertising
This manual is related to the following products: