Installation procedure, Mechanical installation – Super Systems eFLO User Manual

Page 6

Advertising
background image

eFlo Electronic Flow Meter Operations Manual

Super Systems Inc.

Page 6 of 25

Part Number

Item

Explanation

31182

Pressure Transducer

Measures the pressure drop

through the Element and provides

that signal to the electronic

boards for calculation of the gas

flow.

31542

Flow Board

The primary electronics board

containing all of the circuitry and

input and output pins.

31657

Motor Control Board

The electronics board that

controls the operation of the

motor.

20823

Cable

6 foot pigtail for RS485, 4-20mA

input, 4-20mA output and 24VDC

power. Note that use of the cable

is not mandatory: connections

can be made directly to terminals

if desired.

Table 2 - Replacement Parts List

Installation Procedure

Installing the eFlo unit consists of a mechanical installation and an electrical installation. The

mechanical installation includes mounting as well as inlet and outlet piping. The eFlo unit will

be assembled prior to shipment. Before beginning installation:

Ensure that all fittings and connections are tightly secured prior to beginning

installation.

Ensure that all expected components are present. Contact SSi at (513) 772-0060 if you

have questions.

Mechanical Installation

Secure mounting is achieved by correctly and securely installing the required piping in the inlet

and outlet connections of the eFlo unit. Note the distance between the centers of inlet and

outlet openings is 8.3” (21.1cm). The outlet openings themselves measure 1.25” NPT. The

locations of these connections are shown in Figure 2. Use of bushings or reducers at these

connections is okay as long as the maximum flow rate can still be achieved. Contact SSi at (513)

772-0060 for questions about pipe sizing.