Milstanagmessagetype element, Content, Sync-mode – Wavecom W-RCI (Remote Control) V8.7.0 User Manual
Page 25: Data-bits, Parity-bits, Stop-bits, Bit-sequence, Data-polarity, Auto-detect, Display-format
XML SDK V8.7.0 Remote Control Interface
Command messages
17
Content
The content is the product key to be set.
MilStanagMessageType element
<Message version="1.0">
<Command>
<Set>
<MilStanagMessageType sync-mode="async" data-bits="7" parity-bits="none"
stop-bits="0" bit-sequence="lsb" data-polarity=”nor” display-format="ita5"
auto-detect=”idle”/>
</Set>
</Command>
</Message>
Attribute List
sync-mode
The sync mode is a choice between "async" and "sync".
data-bits
The number of data bits. The valid range is 5 to 8.
parity-bits
The parity bit is a choice among "none", “even”, “odd”, “mark” and "space".
stop-bits
The number of stop bits. The valid range is 0 to 2.
Valid attribute combinations:
sync-mode
parity-bits
stop-bits
“async”
all variants
1 or 2
“sync”
“none” only
0
bit-sequence
The bit sequence order is a choice between "lsb" and "msb".
data-polarity
The data polarity is a choice between "nor" and "inv".
auto-detect
The auto-detect command is a choice between “start”, and “stop”.
The auto-detect information is a choice between “idle”, “active”, and “success”.
display-format
The display format is a choice among "ita5", "ita2", "hex" and "binary".
The Stanag-4285 mode includes an additional display format, "s5066".
Valid combinations:
display-format
data-bits
“ita5”
7 or 8 data bits; default is 7 data bits
“ita2”
5 data bits only
“hex”
5 to 8 data bits
“binary”
5 to 8 data bits
“s5066”
5, 7 and 8 data bits; default is 7 data bits
Note: Depending attributes are forced to valid values if their current values are not compatible with the
updated reference attribute. For example, if display-format is changed from “ita2” to “ita5”, then data-
bits is set to 7 bits.