Milstanagmessagetype element, Content, Sync-mode – Wavecom W-RCI (Remote Control) V8.7.0 User Manual

Page 25: Data-bits, Parity-bits, Stop-bits, Bit-sequence, Data-polarity, Auto-detect, Display-format

Advertising
background image

XML SDK V8.7.0 Remote Control Interface

Command messages

17

Content

The content is the product key to be set.

MilStanagMessageType element

<Message version="1.0">
<Command>
<Set>
<MilStanagMessageType sync-mode="async" data-bits="7" parity-bits="none"
stop-bits="0" bit-sequence="lsb" data-polarity=”nor” display-format="ita5"
auto-detect=”idle”/>
</Set>
</Command>
</Message>


Attribute List

sync-mode

The sync mode is a choice between "async" and "sync".

data-bits

The number of data bits. The valid range is 5 to 8.

parity-bits

The parity bit is a choice among "none", “even”, “odd”, “mark” and "space".

stop-bits

The number of stop bits. The valid range is 0 to 2.
Valid attribute combinations:

sync-mode

parity-bits

stop-bits

“async”

all variants

1 or 2

“sync”

“none” only

0

bit-sequence

The bit sequence order is a choice between "lsb" and "msb".

data-polarity

The data polarity is a choice between "nor" and "inv".

auto-detect

The auto-detect command is a choice between “start”, and “stop”.
The auto-detect information is a choice between “idle”, “active”, and “success”.

display-format

The display format is a choice among "ita5", "ita2", "hex" and "binary".
The Stanag-4285 mode includes an additional display format, "s5066".
Valid combinations:

display-format

data-bits

“ita5”

7 or 8 data bits; default is 7 data bits

“ita2”

5 data bits only

“hex”

5 to 8 data bits

“binary”

5 to 8 data bits

“s5066”

5, 7 and 8 data bits; default is 7 data bits

Note: Depending attributes are forced to valid values if their current values are not compatible with the
updated reference attribute. For example, if display-format is changed from “ita2” to “ita5”, then data-
bits
is set to 7 bits.