4-4 Level 1 Process Air Temperature Controller

Standard AEC/Whitlock dryers use a microprocessor-based PID temperature controller for
maintaining process air temperature. The controller is a modular, self-contained unit you can
remove from the mounting housing. All parameters except for the process air set point are set
and adjusted at the factory; no field adjustment to the internal controls is normally necessary.

4-5 Level 1 PLC LED Indicators

Input LED Indicators

Process Blower On (Indicator 000)
The amber

Process Blower On

LED lights when the blower contactor energizes.


Hi-Process Air Temp (Indicator 001)
The amber

Hi-Process Air Temp

LED lights when the process air temperature is within an

acceptable operating range. The LED turns off during a high process air temperature condition.

Output LED Indicators

Left Bed In Regen (Indicator 100)
The amber

Left Bed In Regen

LED lights when the left bed is in regeneration.


Right Bed In Regen (Indicator 101)
The amber

Right Bed In Regen

LED lights when the right bed is in regeneration.


Left Bed Heater On (Indicator 102)
The amber

Left Bed Heater On

LED lights when the left bed regenerates and is in the heat-up

portion of the regeneration cycle.

Right Bed Heater On (Indicator 103)
The amber

Right Bed Heater On

LED lights when the right bed regenerates and is in the heat-

up portion of the regeneration cycle.

Status LED Indicators

Power Indicator
The green

Power

LED lights when power is applied to the PLC (100-240 VAC, 50/60 Hz).

Page 28

WDMR and WDFR Series Dehumidifying Dryers