Determining Temperature Controller Errors or Sensor Errors

Using a Thermocouple
If the controller displays a temperature that is close to room temperature (70ºF/21ºC) when you
short-circuit controller input terminals, the controller is normal and the sensor is probably
broken, short-circuited, or incorrectly wired.

Using a Platinum Resistance Thermometer
If the controller displays a temperature of about 0.0°C (32ºF) when you insert a 100-ohm resistor
between terminals

A

and

–B

of the controller, and you short-circuit controller terminals

+B

and

–B

, the controller is normal and the sensor is probably broken, short-circuited, or incorrectly

wired.