Process value numeric led, Set value numeric led, High temperature alarm indicator – AEC WD 350 through WD3000 Dehumidifying Dryers User Manual

Page 38: 5 level 2 process air temperature controller, 6 level 2 temperature controller led indicators

Advertising
background image

5-5 Level 2 Process Air Temperature Controller

Your AEC/Whitlock dryer uses a microprocessor-based PID controller for maintaining process
air temperature. The controller is a modular, self-contained unit that can slide out from the
housing. All parameters except the process air set point are set and adjusted at the factory; no
field adjustment to the internal controls is normally necessary.

Figure 14

Level 2 PLC Controller Details

1 8 0

1 8 0

SV

PV

OUT

STOP

HB

ALM2

ALM1

ºF

Output indicator

Stop indicator

Mode key

Level key

Not used
Down key
Up key

Not used

High temperature alarm indicator

Process air temperature set point

Process air temperature


5-6 Level 2 Temperature Controller LED Indicators

Process Value Numeric LED

—— PV ——

During normal operation, the red process value (

PV

) numeric LED indicator displays the process

temperature at the To Process thermocouple. It also lists parameters during setup and error
messages if any errors occur.

Set Value Numeric LED

—— SV ——

During normal operation, the green set value (

SV

) numeric LED indicator displays the process

set point you selected for the dryer. The dryer then maintains this set point temperature. This
LED indicator also displays parameter and pre-set function values during setup.

ALM1

High Temperature Alarm Indicator

The

ALM1

high-temperature alarm indicator lights when the process temperature exceeds the set

point temperature by more than the alarm deviation value. This alarm output de-energizes the
heaters. Heaters re-energize when the temperature falls within the acceptable range.

WDMR and WDFR Series Dehumidifying Dryers

Page 37