24

RECOMMENDED

MINIMUM CHIMNEY

HEIGHTS

The chimney must be at least 3 ft. (.9m) higher than the highest point where it passes through the roof and
at least 2 ft. (.6m) higher than the highest part of the roof or structure within 10 ft. (3m) of the chimney,
measured horizontally. These are code requirements and cannot guarantee a suitable draft. We rec-
ommend using a minimum total system height of 12 ft. (3.6m), measured from the flue collar to the bottom of
the chimney cap)

# OF ELBOWS

ELEVATION (FT)

ABOVE SEA

LEVEL

0

2 x 15

o

4 x 15

o

o

2 x 30

o

4 x 30

o

2 x 45

o

4 x 45

o

0-1000

12.0

13.0

14.0

15.0

18.0

16.0

20.0

1000-2000

12.5

13.5

14.5

15.5

19.0

16.5

21.0

2000-3000

13.0

14.0

15.0

16.0

19.5

17.0

21.5

3000-4000

13.5

14.5

15.5

17.0

20.0

18.0

22.5

4000-5000

14.0

15.0

16.0

17.5

21.0

18.5

23.0

5000-6000

14.5

15.5

17.0

18.0

21.5

19.0

24.0

6000-7000

15.0

16.0

17.5

18.5

22.5

20.0

25.0

7000-8000

15.5

16.5

18.0

19.0

23.0

20.5

25.5

8000-9000

16.0

17.0

18.5

20.0

24.0

21.0

26.5

9000-10000

16.5

17.5

19.0

20.5

24.5

22.0

27.0

NOTE: No more than two offsets (four elbows) allowed. Two 45

o

elbows equal one 90

o

elbow.

(Measured from the top of the unit)

Recommended Flue Height

Elevation

Example a)

Example b)

0'

18'

21'

1000'

18.72'

21.84'

2000'

19.44'

22.68'

5000'

21.60'

25.20'

1) At sea level minimum height is 12'
straight, off the top of the appliance.
2) Add the following vertical height to
compensate for:

45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T" = 3 ft.

Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above
sea level.
Examples:
a)
1-1/2 ft. of horizontal run = 3 ft. one
"T" = 3 ft.

Total Addition (at sea level) = 6 ft.


b) One 90 deg. elbow = 2 ft.

2 ft. of horizontal run = 4 ft.

one "T" = 3 ft.

Total Addition (at sea level) = 9 ft.