TROUBLESHOOTING

PROBLEM

CAUSE

CURE

Glass is Dirty

1. Wood is wet

Use dry wood

2. Turning down air control or

damper too soon

Do not turn down until:

there is a good bed of coals

the wood is charred

3. Draft too low – Improper

chimney height and / or di-
ameter

Flue pipe too long, too many

offsets or too large a diame-
ter

Chimney plugged or restricted,
check flue

Provide outside air for combus-
tion

4. Door gasket leakage

Replace gasket

Check latch

5. Excessive Creosote Buildup

See 1,2,3, above

Low Heat Output

1. Wood is wet

Use dry wood

2. Fire too small

Build a larger fire

3. Draft too low

Chimney plugged or restricted,
inspect and clean (See 3 above)

Won't Burn Overnight

1. Air control is set too high

Set control lower

2. Not enough wood

Un-split wood is preferred for over-
night burns

3. Draft too high

Excessive chimney height and / or
diameter

Stove Won't Burn

1. Combustion air supply

blocked

Check outside air supply for ob-
struction

Check that room air cover is
removed

2. Draft too low

Chimney plugged or restricted,
inspect and clean

Chimney / flue pipe oversized
or otherwise unsuitable