Configuration prerequisites, Configuration procedure, Associating track with cfd – H3C Technologies H3C S12500-X Series Switches User Manual
Page 81
73
•
If the BFD detects that the link is operating correctly, the Track module sets the track entry to Positive
state.
Configuration prerequisites
Before you associate Track with BFD, configure the source IP address of BFD echo packets. For more
information, see "
Configuration procedure
To associate Track with BFD:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create a track entry,
associate it with the BFD
session, and specify the delay
time for the Track module to
notify the associated
application module when the
track entry status changes.
track track-entry-number bfd echo interface
interface-type interface-number remote ip
remote-ip local ip local-ip [ delay { negative
negative-time | positive positive-time } * ]
No track entry is created
by default.
Do not configure the
virtual IP address of a
VRRP group as the local or
remote address of a BFD
session.
Associating Track with CFD
CFD functions as follows when it is associated with a track entry:
•
If the CFD detects that the link fails, it informs the track entry of the link failure. The Track module
then sets the track entry to Negative state.
•
If the CFD detects that the link is operating correctly, the Track module sets the track entry to Positive
state.
Configuration prerequisites
Before you associate Track with CFD, enable CFD and create a MEP. For more information, see
"
Configuration procedure
To associate Track with CFD:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create a track entry, associate it
with the CFD session, and
specify the delay time for the
Track module to notify the
associated application module
when the track entry status
changes.
track track-entry-number cfd cc
service-instance instance-id mep mep-id
[ delay { negative negative-time | positive
positive-time } * ]
No track entry is
created by default.