Verifying the configuration, Fspf configuration example, Network requirements – H3C Technologies H3C S12500-X Series Switches User Manual

Page 111

Advertising
background image

102

[SwitchA] interface vfc 3

[SwitchA-Vfc3] fc mode np

[SwitchA-Vfc3] quit

# Configure downlink interfaces VFC 1 and VFC 2.

[SwitchA] interface vfc 1

[SwitchA-Vfc1] fc mode f

[SwitchA-Vfc1] quit

[SwitchA] interface vfc 2

[SwitchA-Vfc2] fc mode f

[SwitchA-Vfc2] quit

Verifying the configuration

# Display the nodes on downlink interfaces and their mapped uplink interfaces.

[SwitchA] display npv login

Server External

Interface VSAN FCID Port WWN Node WWN Interface

Vfc1 1 0x010001 21:00:00:00:c8:00:e4:30 20:00:00:00:c8:60:e4:9a Vfc3

Vfc2 1 0x010002 21:00:00:00:c9:00:e4:30 20:00:00:00:c9:60:e4:9a Vfc3

# Display the status of Switch A.

[SwitchA] display npv status

External Interfaces:

Interface: Vfc3 VSAN tagging mode: Tagging

VSAN State FCID

1 Up 0x010000

Number of External Interfaces: 1

Server Interfaces:

Interface : Vfc1 VSAN tagging mode: Tagging

VSAN State

1 Up

Interface : Vfc2 VSAN tagging mode: Tagging

VSAN State

1 Up

Number of Server Interfaces: 2

# Display the traffic mapping information.

[SwitchA] display npv traffic-map

NPV traffic map information of VSAN 1:

Server Interface External Interface

Vfc1 Vfc3

Vfc2 Vfc3

Advertising
This manual is related to the following products: