Configuring the fabric timers in system view, Configuring the fabric timers in vsan view, Configuring the fabric reconfiguration – H3C Technologies H3C S12500-X Series Switches User Manual

Page 44: Verifying the configuration

Advertising
background image

35

If you perform the configuration in both system view and VSAN view, the configuration made in VSAN

view applies to the VSAN.

Configuring the fabric timers in system view

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the global

distributed service timeout
period.

fc timer distributed-services value

By default, the distributed service
timeout period is 5000

milliseconds.

3.

Configure the global error

detection timeout period.

fc timer error-detect value

By default, the error detection
timeout period is 2000
milliseconds.

4.

Configure the global
resource allocation timeout

period.

fc timer resource-allocation value

By default, the resource allocation
timeout period is 10000

milliseconds.

Configuring the fabric timers in VSAN view

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure the distributed
service timeout period for

the VSAN.

timer distributed-services value

By default, the distributed service
timeout period is 5000 milliseconds.

4.

Configure the error
detection timeout period

for the VSAN.

timer error-detect value

By default, the error detection
timeout period is 2000 milliseconds.

5.

Configure the resource

allocation timeout period
for the VSAN.

timer resource-allocation value

By default, the resource allocation
timeout period is 10000

milliseconds.

Configuring the fabric reconfiguration

IMPORTANT:

The fabric reconfiguration function takes effects only when the fabric configuration function is enabled.

The fabric reconfiguration occurs in the case of a network reconstruction (for example, two fabrics are
merged) or external intervention (for example, the administrator uses a command to initiate

reconfiguration). The fabric reconfiguration triggers principal switch selection, domain ID assignment,

and FC address assignment throughout the fabric.
The fabric reconfiguration includes the following categories:

Advertising