Verifying the configuration, Configuring the allowed domain id list – H3C Technologies H3C S12500-X Series Switches User Manual

Page 53

Advertising
background image

44

[SwitchB-Ten-GigabitEthernet1/0/1] quit

# Create interface VFC 1, and configure it to operate in F mode.

[SwitchB] interface vfc 1

[SwitchB-Vfc1] fc mode f

# Bind interface VFC 1 to interface Ten-GigabitEthernet 1/0/1, and assign it to VSAN 1 as a trunk
port.

[SwitchB-Vfc1] bind interface ten-gigabitethernet 1/0/1

[SwitchB-Vfc1] port trunk vsan 1

[SwitchB-Vfc1] quit

# Assign interface Ten-GigabitEthernet 1/0/1 to VLAN 10 as a trunk port.

[SwitchB] interface ten-gigabitethernet 1/0/1

[SwitchB-Ten-GigabitEthernet1/0/1] port link-type trunk

[SwitchB-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10

[SwitchB-Ten-GigabitEthernet1/0/1] quit

# Create interface VFC 2, and configure it to operate in E mode.

[SwitchB] interface vfc 2

[SwitchB-Vfc2] fc mode e

# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/0/2, and assign it to VSAN 1 as a trunk
port.

[SwitchB-Vfc2] bind interface ten-gigabitethernet 1/0/2

[SwitchB-Vfc2] port trunk vsan 1

[SwitchB-Vfc2] quit

# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.

[SwitchB] interface ten-gigabitethernet 1/0/2

[SwitchB-Ten-GigabitEthernet1/0/2] port link-type trunk

[SwitchB-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10

[SwitchB-Ten-GigabitEthernet1/0/2] quit

# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.

[SwitchB] vlan 10

[SwitchB-vlan10] fcoe enable vsan 1

[SwitchB-vlan10] quit

Verifying the configuration

1.

Verify the configuration on Switch A.

[SwitchA] display fc domain vsan 1

Domain Information of VSAN 1:

Running time information:

State: Stable

Switch WWN: 48:33:43:2d:46:43:1A:1A

Fabric name: 11:11:11:11:11:11:11:11

Priority: 128

Domain ID: 1

Configuration information:

Domain configure: Disabled

Domain auto-reconfigure: Disabled

Advertising