Creating a vsan, Configuring a trunk vsan, Displaying and maintaining vsan – H3C Technologies H3C S12500-X Series Switches User Manual

Page 65: Vsan configuration example, Network requirements, Displaying and maintaining a fabric, Static fabric building configuration example

Advertising
background image

56

Creating a VSAN

Initially, only the default VSAN (VSAN 1) exists. You cannot create or delete VSAN 1. You can create
VSANs 2 to 3839.
To create a VSAN:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Create a VSAN and enter VSAN view.

vsan vsan-id

By default, only the default VSAN
(VSAN 1) exists.

Configuring a trunk VSAN

A VFC interface can be assigned to multiple VSANs as a trunk port.
If you assign an interface to VSANs as a trunk port multiple times, the final trunk VSAN list is the set of

all the VSANs to which you have assigned the interface.
To assign an interface to the specified VSANs as trunk ports:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VFC interface view.

interface vfc interface-number

N/A

3.

Assign the interface to the
specified VSANs as a trunk

port so that the interface

allows the specified VSANs

to pass through.

port trunk vsan vsan-id-list

By default, a VFC interface does not
belong to any VSAN (including

VSAN 1) as a trunk port.
You can assign an interface to a

nonexistent VSAN as a trunk port.

Displaying and maintaining VSAN

Execute display commands in any view.

Task Command

Display the member ports of the VSAN.

display vsan [ vsan-id ] port-member

VSAN configuration example

Network requirements

As shown in

Figure 21

, configure the SAN to meet the following requirements:

Server A can read and write only the data of Disk A and Disk B.

Advertising
This manual is related to the following products: