Configuring the shortest spf calculation interval, Configuring the minimum lsr receiving interval, Configuring the minimum lsr refresh interval – H3C Technologies H3C S12500-X Series Switches User Manual

Page 76

Advertising
background image

67

Configuring the shortest SPF calculation interval

SPF calculations occur when the LSDB changes. To limit the amount of CPU resources consumed by

frequent SPF calculations, you can change the shortest SPF calculation interval.
The shortest SPF calculation interval defines the minimum interval between two consecutive SPF
calculations. A smaller value means that FSPF responds faster to fabric changes by recalculating routes

in a VSAN, but it requires more CPU resources.
To configure the shortest SPF calculation interval:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure the shortest SPF

calculation interval.

fspf spf-hold-time value

The default setting is 0 second.

Configuring the minimum LSR receiving interval

The minimum LSR receiving interval specifies the time between receiving LSRs in a VSAN. Any LSR

instances of the same LSR received within this time are dropped. This helps avoid frequent SPF
calculations caused by LSDB updating.
To configure the minimum LSR receiving interval:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure the minimum

LSR receiving interval.

fspf min-ls-arrival value

The default setting is 1 second.

Configuring the minimum LSR refresh interval

The minimum LSR refresh interval specifies the interval at which LSRs are refreshed. To reduce SPF

calculations and LSR flooding in a fabric caused by frequent LSR refreshing, the switch cannot refresh

local LSRs within this interval.
To configure the minimum LSR refresh interval:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure the minimum
LSR refresh interval.

fspf min-ls-interval value

The default setting is 5 seconds.

Advertising