34

H3C recommends that you configure domain IDs of the same type for all switches in a VSAN.
To configure a domain ID for a switch:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure a domain ID for

the switch.

domain-id domain-id { preferred |
static }

By default, the domain ID of a switch is
0 and is of the preferred type.

Configuring the mapping between the N_Port
WWN and an FC address

If you bind the WWN of an N_Port to an FC address, when the N_Port requests an FC address, the

switch assigns the bound FC address to it.
The WWN of an N_Port can be bound to only one FC address, and vice versa.
The N-Port here indicates an N_Port on a node or an NP_Port on an NPV switch.
To bind the WWN of an N_Port to an FC address:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Bind the WWN of an

N_Port to an FC address.

wwn wwn-value area-port-id
area-port-id-value

By default, no binding is
configured.
If the N_Port has been assigned
another FC address or the FC

address has been assigned to

another N_Port, the binding is
not allowed.

Configuring the fabric timers

The fabric operation involves the following timers:

Distributed service timeout period

Error detection timeout period

Resource allocation timeout period

For more information about these timers, see FC-related protocols and standards.