Vxlan is-is configuration example, Network requirements, Configuration procedure – H3C Technologies H3C S12500-X Series Switches User Manual

Page 57

Advertising
background image

50

Display VXLAN IS-IS information for
tunnel interfaces.

display vxlan isis tunnel [ tunnel-number ]

Clear data for the VXLAN IS-IS process. reset vxlan isis

VXLAN IS-IS configuration example

Network requirements

As shown in

Figure 11

:

Configure unicast-mode VXLANs on Switch A, Switch B, and Switch C to provide Layer 2
connectivity for the VMs across different sites.

Manually set up VXLAN tunnels between the VTEPs.

Configure VXLAN IS-IS to advertise MAC reachability information and automate VXLAN tunnel
assignment. Use VXLAN 11111 as the reserved VXLAN for VXLAN IS-IS.

Table 4

shows the VLAN and VXLAN mapping scheme.

Table 4 VXLAN and VLAN mappings

VMs VLAN

VXLAN

VTEPs

VM 1, VM 5

VLAN 2

VXLAN 10000

Switch A, Switch B

VM 2, VM 6

VLAN 3

VXLAN 10001

Switch A, Switch B

VM 3, VM 7

VLAN 4

VXLAN 10002

Switch A, Switch C

VM 4, VM 8

VLAN 5

VXLAN 10003

Switch A, Switch C

Figure 11 Network diagram

Configuration procedure

1.

Configure IP addresses and routing settings:

Advertising
This manual is related to the following products: