Enter 3 on the BootWare main menu to enter the Ethernet submenu. Then, enter 5 on the submenu to
enter the Ethernet interface configuration interface:

============================<ETHERNET PARAMETER SET>============================

|Note: '.' = Clear field. |

| '-' = Go to previous field. |

| Ctrl+D = Quit. |

================================================================================

Protocol (FTP or TFTP) :tftp

Load File Name :host

:main.bin

Target File Name :target

:main.bin

Server IP Address :192.168.0.250

Server IP Address :192.168.0.1

Local IP Address :192.168.0.10

Gateway IP Address :0.0.0.0

z

When configuring a parameter, you can enter a new value directly, or press Enter to accept the
default value, which is after the colon. Type a dot (.) to clear the input, a hyphen (-) to return to the
previous parameter field, and a combination of ^D (namely, Ctrl+D) to exit the parameter
configuration interface.

z

The WX5002V2 supports only GigabitEthernet 1/0/1 for application upgrade.

Upgrading Applications Through an Ethernet Interface

The Trivial File Transfer Protocol (TFTP) is a TCP/IP protocol used for file transfer between client and
server. It provides a simple and low-cost file transfer service. TFTP provides unreliable data transfer
over UDP and does not provide any access authorization and authentication mechanism. It employs the
timeout retransmission method to implement best-effort delivery of data. Compared with FTP, TFTP has
a much smaller software size.

Follow these steps to upgrade an application file through the management Ethernet interface (10/100
Base-TX):

Step1

Set up a software upgrade environment.

Figure 5-7

Set up a software upgrade environment