Using the densité frame control panel, Using the densité frame control, Panel – Grass Valley Kaleido-MX (1RU) v.7.80 User Manual

Page 40: Using the densité, Frame control panel

Advertising
background image

26

Operation

Using the Densité Frame Control Panel

Output module FlexBridge input LEDs

Kaleido-MX (1RU) have 2 or 4 LEDs (depending on model) monitoring the status of the
FlexBridge inputs located on their rear connector panel. The FlexBridge inputs are reserved
for future expansion.

SFP LEDs

Kaleido-MX (1RU) have 4 or 8 SFP LEDs (depending on model) located on the rear
connector panel. These LEDs are always OFF, and currently not relevant.

Using the Densité Frame Control Panel

All of the cards installed in a Densité frame are connected to the frame’s controller card,
which handles all interaction between the cards and the outside world. There are no
operating controls located on the cards themselves. The controller supports remote
operation via its Ethernet ports, and local operation using its integrated control panel.

The local control panel is fastened to the controller card, and consists of a display unit
capable of displaying two lines of text, each 16 characters in length, and five buttons.

Densité CPU-ETH2 local control panel

LED

Meaning

Green

HD-SDI or 3G-SDI signal detected

Red

No SDI signal detected

Flexbridge input LEDs on
Kaleido-MX-16x2 rear panel
(future use)

4 SFP LEDs on Kaleido-MX-16x2
rear panel (future use)

Advertising