Control Panel Overview

Figure 140. Multi-Function Module Example

The following describes the Multi-Function Module organization
(

Figure 140

):

Function button row (top left), with six Keyer (

Key 1-Key 6

) buttons and

Wipe 1

and

Wipe 2

buttons for delegating to a keyer for the selected ME.

Below the function row is the main delegation area with buttons and
status display:

The first column (left) are radio buttons for delegating the MEs, for
example

ME 1

,

ME 2

,

ME 3

, and

PGM

as shown in

Figure 140

.

Adel

button (right)—ON supports ‘Auto Delegation’ of this module

when selecting a source on a key bus, delegating a keyer in the bus
control section of any Source Select Module, selecting a keyer in any
Next Transition section of any ME, and selecting Wipe 1 or Wipe 2
in any Transition Module,

Last

button (far right)—Toggles between current and previous dele-

gation modes,

HOME

button (only displayed when not at the Home position)—

Moves the display to the top or ‘Home’ level,

Wipe

ipe

1

Key

Key

5

Key

Key

3

Key

Key

1

Wipe

ipe

2

Key

Key

6

Key

Key

4

Key

Key

2

ME1




Adel Last

ME2 Wipe

eDPM

iDPM

Matt

Mask

Keys

ME3 Swap

SSel Cams

Copy

Devs

PGM Panl