Grass Valley M-2100 User Manual

Page 17

Advertising
background image

MMCP Installation/Operation Manual

1-9

Control Panel Cabling

Use the following procedure to set the IP address using the Netburner PC
tool.

1.

Connect a PC and one MMCP to the same 10 BaseT Ethernet network.

Note

Only one panel at a time should be connected to the PC to allow positive iden-
tification of the panel to be programmed.

2.

Open the Netburner IPSetup.exe application and locate the panel on
the network as shown in

Figure 1-10

. The application will find

Netburner devices on the network and identify them by their MAC
addresses.

3.

Type in the desired IP address in the

IP

boxes.

4.

Set the Subnet Mask in the

Network Mask

boxes to 255.255.255.0.

5.

Set the

GateWay

IP address to 0.0.0.0.

6.

Set the

DNS

IP address to 0.0.0.0.

7.

When finished, click on the

Close

button.

8.

The panel must be rebooted for the new IP address to take effect.
Remove power momentarily to reboot.

Figure 1-10. Netburner IPSetup PC Tool

Advertising