2.

Press a

Key Select

button. All setup buttons and knobs associated with

that keyer are changed to a default configuration.

3.

Release the

Key Select

button and its tally will remain what it was before

it was pressed.

Keyer defaults can be set regardless of whether the key is visible on either
the Program or Preset bus. It does not matter when the

Mode/Function

button

is released as long as

Mode/Function

was pressed when the

Key Select

button

was pressed.

This default configuration can be the factory default, or a default configu-
ration defined by the user during system configuration.

Linear/Luminance Key Unity Clip and Gain Default

A keyer must be in modify mode.

1.

Press and hold the

Mode/Function

button.

2.

Press and release the

Linear

button. The tally of the

Linear

button remains

unchanged. The Key Clip and Gain parameters are set to default
values.

Reset Key Parameters

You can reset the current keyer parameters by pressing and holding the

Mode/Function

button and then pressing the appropriate

Key Select

button.

Table 2-5. Factory Default Recall Parameters

Border & Shadow

off (border/shadow luminance = 50%)

External Key

on

Linear Key

on

Clip

50%

Opacity

100%

Matte fill

off

50% Luminance

Hue

Green

Saturation

0%

Unity Gain

Advertising