115
MAESTRO User Manual
Section 2 — The Maestro Configuration Editor
Trigger Sense
Selections are:
•
High - close the contact when a transition begins and open when the
transition is complete, or
•
Low - open the contact when a transition begins and close when the tran-
sition is complete.
When finished configuring the table, select the
Apply
or
OK
button
.
The
Name of the GPIO Definition set will now appear in the set panel. The set
is assigned to the appropriate Maestro channel (Processor) using the
Channel Setup table.
Source Tally Mode
Source tally mode, also referred to as “stand-alone tally,” can be used for
either Encore- or Jupiter-controlled systems.
When the GPIO Definition table is first opened, the editor will open a set
panel. Create a name for the GPIO table, then select an Input set, and then
select “New.” (The table is assigned to a Maestro channel using the Channel
Setup table.) See
.
Note
Source Tally mode will not be available unless an Input Set Dependency is
applied to the GPIO Definition as illustrated in
.