7 repeat steps 2-6 for the remaining control card, Setting up ec9535 switch points, How to select switch point settings for the ec9535 – Grass Valley UniConfi NVISION Series v.1.3 User Manual

Page 135: Setting up ec9535 switch, Points, Configuring ec9535

Advertising
background image

UniConfig Configuration Application • User’s Guide

123

12. Configuring EC9535

Setting Up EC9535 Switch Points

The following is a list of each field and the corresponding information to be entered:

6 Click

Write All

to writes changes to the control card.

7 Repeat steps 2–6 for the remaining control card.

Setting Up EC9535 Switch Points

A “switch point” is a point in time in which an output is switched from the current source to a new
source. Different video and audio formats require different switch points to prevent data or picture
disturbances. UniConfig enables you to set switch point parameters for individual outputs. Switch
points are initially set up as part of configuring the EC9535.

Switch points are managed through the ‘Switch Point Setup’ window. Reference information for
video and audio signals is through reference connections housed on the EC9535. For video refer-
ence signals, there are two connections labeled ‘VIDEO REF’. Both video reference connections
can reference the same signal or each connection can reference a unique signal. For audio reference
signals, there are two connections labeled ‘AES REF’. One or both connections are connected to a
stable source of AES3 at a sample rate of 48

kHz. If both reference connections are connected, one

acts as a backup, automatically providing a reference signal should an AES reference source fail.

Important: in general, the video reference and AES reference on the EC9535 are not used. The
reference signals are received from the router connected to the EC9535. If you plan to connect ref-
erence signals to the EC9535, please contact Technical Support before proceeding. (See

Technical

Support Contact Information

on page iii.)

How to Select Switch Point

Settings for the EC9535

1 Launch UniConfig. (See

Launching UniConfig

on page 9.)

2 Select a control card. (See

Selecting a Control Card

on page 10.)

UniConfig Field

Description

Values

Level

Numeric value identifying a particular configured partition.

0

Physical Inputs

Input connectors this partition starts and ends with.

1–1024

Controller Input

Logical number this partition starts with.

1

Physical Outputs

Output connectors this partition starts and ends with.

1–1024

Controller Output

The controller partition starts with the logical number zero.

0

Signal Type

Defines what software signal type in use.

From the

‘Signal

Type’ drop-down list, select the signal type ‘Video,

Async, AES, Timecode’.

Video, Async,
AES, Timecode

Advertising