8 specifications, 8specifications – HEIDENHAIN PWM 20 User Manual

Page 27

Advertising
background image

PWM 20

Operating Instructions

en

29

8

Specifications

Electrical data

Power supply

100 V AC to 240 V AC (±10 %),

50 Hz to 60 Hz (±2 Hz)

Approx. 20 W

24 V DC (±10 %),

approx. 20 W

Measurement
of supply vol-
tage and supp-
ly current

Voltage: ± 0.5 % (min. ±5 mV)
Current: ± 2 % (min. ±1 mA)

Encoder input X1

15-pin D-sub connection, female

Support depends on the software version of the ATS soft-

ware

Adjustable from 2 V to 30 V with/without remote sense

control

Current limitation 750 mA

Information about the cable lengths:

The specified cable length applies when
HEIDENHAIN cables are used. The supply
voltage range of the encoder must be
maintained.

EnDat 2.1/
EnDat 2.2

1

Cable length: Functional limit < 100 m,

depending on the clock frequency

Compliance with test limits < 2 m

(only incremental signals)

Input frequency of incremental signals

3

:

< 1000 kHz

1 V

PP

1

Cable length: Functional limit < 150 m

Compliance with test limits < 2 m

Input frequency of incremental signals

2

:

< 1000 kHz

TTL

Cable length: Functional limit

< 100 m/50 m, depending on min. edge

separation

Compliance with test limits < 2 m

Input frequency of incremental signals :

< 1000 kHz

Edge separation > 20 ns

HTL

4

Cable length: Functional limit < 300 m,

depending on min. edge separation

Compliance with test limits < 2 m

Input frequency of incremental signals :

< 500 kHz

Edge separation > 20 ns

Encoder input X1

11 µA

PP

1

Cable length: Functional limit < 30 m

Compliance with test limits < 2 m

Input frequency of incremental signals

2

:

< 300 kHz

Fanuc,
Mitsubishi,
Yaskawa
Panasonic

Cable length: Functional limit < 30 m

SSI

Cable length: Functional limit < 100 m

1

Incremental signals are displayed in inverted form

2

Cutoff frequency, reduced by the ATS software to 100 kHz for
certain measuring functions

3

If supported by the connected encoder

4

HTL only for service purposes via external adapter,
e.g. ID 1093210-01

Encoder output X2

15-pin D-sub connection, male

Feed-through
mode of X1

Directly or via SA xxx signal adapter, de-
pending on the ATS version

EnDat 2.1/EnDat 2.2

Fanuc/Mitsubishi

1 V

PP

TTL

11 µA

PP

External functions X3

6-pin Mini-DIN-connection, female

MSB output

For EnDat 2.1/2.2

Encoder input X4

8+2-pin RJ-45 connection, female

DRIVE-CLiQ

1

Only for HEIDENHAIN encoders

1

DRIVE-CLiQ is a registered trademark of Siemens
Aktiengesellschaft, only HEIDENHAIN encoders are supported

Data interface X5

USB

USB 2.0 high speed

1

1

Lower USB transfer rates can result in measuring errors.

Advertising