2.5 Alarm input / output installation

The EDR910/1610 alarm inputs can be used for recording start or recording rate
adjustment. Furthermore, alarm reactions such as camera switching to monitors, buzzer,
e-mail and network alarm are available. An alarm output relay can be switched if

required.

EDR910 provides 9 alarm inputs, EDR1610 provides 16. All inputs are programmable
NO/NC.


Inputs have to be switched through dry contacts.


The relay provide a dry NO/NC contact.

All settings are programmed in the ALARM menu.

Use either the 25-pin Sub-D plug or the included adaptor board for connection.

Pin assignment Sub-D plug

Pin assignment adaptor board








(*) only EDR1610


Descriptions:


ALMINxx:

Alarm input xx (1~9/16)

GND:

common ground for alarm inputs

ALM_COM: output relay , contact root
ALM_NO:

output relay , NO contact

ALM_NC:

output relay , NC contact

ALMRST:

Alarm reset, control input for alarm

reset, for dry NO contact

towards GND

DISKFULL: OC output contact for signal

„HDD full“, switches to GND

REC_IN:

Control contact for recording start

SPARE_IN / OUT: reserved

Pin Description Pin Description

1 GND

15

ALM13*

2 ALM1

16

ALM14*

3 ALM2

17

ALM15*

4 ALM3

18

ALM16*

5 ALM4

19

ALMRST0

6 ALM5

20

REC

7 ALM6

21

GND

8 GND

22

SPARE-IN

9 ALM7

23

DISKFUL

10 ALM8

24 SPARE-OUT

11 ALM9

25 ALM-NC

12 ALM10*

26 ALM-NO

13 ALM11*

27 ALM-COM

14 ALM12*

28 GND

Pin Description Pin Description

1 GND

14

ALM13*

2 ALM1

15

ALM14*

3 ALM2

16

ALM15*

4 ALM3

17

ALM16*

5 ALM4

18

ALMRST0

6 ALM5

19

REC

7 ALM6

20

SPARE-IN

8 ALM7

21

DISKFUL

9 ALM8

22

SPARE-OUT

10 ALM9

23 ALM-NC

11 ALM10*

24 ALM-NO

12 ALM11*

25 ALM-COM

13 ALM12*

NC contact alarm input connection:

Output relay in idle state:

NO contact alarm input connection: