EverFocus EDR-1610A User Manual

Page 49

Advertising
background image

EDR910_1610_ma_en_rev1

00

- 49 -

3.11.4 HDD FULL


In operation mode HDD FULL: STOP (setting in RECORDING menu), the recording

process is stopped if the harddisk is full. Define the alarm reactions in this menu item:

(1) BUZZER:

By selecting “ENABLE”, the buzzer is activated.


(2) ALARM OUTPUT:

Output relay activation.


1

Output relay switches upon alarm.

NONE

no output relay reaction upon alarm.

(3) ALARM DURATION: Alarm duration adjustment from 1~99 seconds or permanent

(4) NETWORK ALARM: YES:

Network alarm activated (for settings refer to

NETWORK

menu)

Network alarm reception requires optional

PowerCon

software.

NO:

No network alarm transmission


(5) EMAIL:

YES:

Alarm email transmission (for settings refer to

NETWORK

menu).

NO:

No email alarm transmission.

WARNING SETUP MENU

FAN

FAULT

BUZZER

ENABLE

HDD TEMP.

ALARM OUTPUT

1

NO HDD

ALARM DURATION

PERMANENT

HDD FULL

NETWORK ALARM

NO

EMAIL

NO