(5) REC QUALITY:

Individual recording quality setting for this camera (within

the resolution defined in RECORDING menu):


SUPERIOR

HIGH

STANDARD
BASIC

LOW

LOWER


Using the VBR (Variable Bit Rate) method, the storage

requirement per image depends on the image’s colour and

contrast content and captured motion.

For recording time sample tables, please refer to

Appendix D.


(6) REC SPEED ON TIME ZONE:

The EDR DVR offers 8 different timers for scheduled

recording. The settings of the last row “N” (normal) apply

to those periods not captured by a timer schedule (setup

in

TIMER

menu)

For recording rate, the following steps are available:
1;2;3;4;5;6;8;10;12,5;25 images/s.

In case no timer is activated, the DVR only operates

according to the settings of row “N”.

TP:

Timer program 1~8, schedule setup and activation are

defined in the TIMER menu.

N:

(Normal) all periods not captured by a timer schedule.

In case no timer is activated, the DVR only operates

according to these settings.

NORMAL:

IPS recording rate for manual or scheduled recording and

recording

controlled

through

“REC IN” input contact. The

maximum image rate is limited to:

Max. image rate per camera = max. DVR recording rate /

number of installed cameras.

Max. DVR recording rate depends on recording resolution:

360x288: 100 images / second

720x288: 50 images / second

720x576: 25 images / second

Example:
EDR1610 with 12 installed cameras, resolution 720x288:

50 IPS : 12 = 4,1 IPS > maximum adjustable recording
rate per camera: 4 IPS


EVENT
:

IPS recording rate for event recordings (alarm contacts,

motion detection), maximum adjustable recording rate is

25

IPS.

ACT

(active): Indication of whether the individual timer is activated.

Settings are carried out in TIMER menu.

ON: timer activated; OFF: timer deactivated