(6) MULTICAST:

If the DVR is connected to a server system, which provide Multicast mode, settings for
this mode can be done here.

YES:

Multicast mode ON

NO:

Multicast mode OFF

IP - ADRESS:

IP-adress of Multicast server

PORT:

Port of Multicast - server


(7) HTTP PORT:


Default setting for this port is: 80. The port can be changed if necessary.

(8) CONTROL PORT:

Default setting for this port is: 1600. The port can be changed if necessary.

(9) DATA PORT:

Default setting for this port is: 37260. The port can be changed if necessary.

ATTENTION: If several users simultaneously access the DVR via network, each user

requires a DATA PORT (max. 4 users). Upon activating ports, e.g. in firewalls, the
following ports have to be opened additionally:


DATA

PORT

+1

DATA

PORT

+2

DATA

PORT

+3


Example:
Dataport 37260 > ports to be opened : 37260, 37261, 37262, 37263

(10) BW control:

Network bandwidth control, setting of maximum network bandwidth usage in the range 0
~ 8192 KB/s.


(11) MAC ADDR:


Display of network interface MAC address (cannot be changed).

3.7.2 ALARM (Network alarm)

Having installed the optionally available PowerCon software, the DVR can transmit a
network alarm to up to 3 recipiants in case of event.

NETWORK SETUP MENU

CONFIG

PROTOCOL

UDP

ALARM

PORT

NUMBER 01600

EMAIL

UNIQUE ID

_ _ _ _ _ _ _ _ _

PASSWORD
PPPoE

SERVER1

192.168.001.122

DDNS

SERVER2

192.168.001.123

SERVER3 192.168.001.124