3.11.2 HDD TEMP.


The enduring HDD temperature surveillance guarantees an alarm reaction in case the

threshold value is exceeded.

There may be several reasons for HDD temperature excess:

• Exceedance of the max. tolerable ambient temperature (40°C), e.g. upon

installation in an electrical cabinet with inadequate ventilation

• After-effect upon fan failure

• HDD defect


(1) BUZZER:

By selecting “ENABLE”, the buzzer is activated upon HDD

temperature excess.


(2) ALARM OUTPUT:

Output relay activation.


1:

Output relay switches upon alarm.

NONE:

no output relay reaction upon alarm.

(3) ALARM DURATION: PERMANENT This value cannot be changed, alarm is

automatically

switched off after problem has

been

solved.


(4) NETWORK ALARM: YES:

Network alarm activated (for settings refer to

NETWORK

menu)

Network alarm reception requires optional

PowerCon software.

NO:

No network alarm transmission


(5) EMAIL:

YES:

Alarm email transmission (for settings refer

to NETWORK menu).

NO:

No email alarm transmission.

(6) STOP RECORD

YES:

Recording process is stopped to avoid further

temperature rise and HDD damage.

NO:

Recording process continues.

WARNING SETUP MENU

FAN

FAULT

BUZZER

ENABLE

HDD TEMP.

ALARM OUTPUT

1

NO HDD

ALARM DURATION

PERMANENT

HDD FULL

NETWORK ALARM

NO

EMAIL

NO

STOP

RECORD

YES