8 frequency reference bias/gain (analog), Frequency reference bias/gain (analog) -8 – Yaskawa V7 Drives User Manual

Page 60

Advertising
background image

5-8

ADJUSTMENT PROCEDURE:

1.

With no input, adjust Bias (

n061 setting) until an output of

0.0 Hz is obtained.

2.

With full scale input, adjust Gain (

n060 setting) until an output

of 60.0 Hz (or other desired max. output frequency) is obtained.

NOTE: Follow the same adjustment procedure for other desired frequency setpoints.

n060 : Analog Frequency Reference Gain

Factory setting:

100 %

Range: 0 to 255 %

Sets the auto-speed frequency command gain,
in increments of 1%.

n061 : Analog Frequency Reference Bias

Factory setting:

0 %

Range: -100 to 100 %

10V

FREQ. REF.
INPUT (V)

FREQ.
REF.
(%)

BIAS

(+)

()

0V

100%

0%

–100%

BIAS

5.8 FREQUENCY REFERENCE BIAS/GAIN (ANALOG)

For inverse-acting frequency reference

1.

Begin with

n060 & n061 settings as shown below.

2.

Fine tune as indicated above.

n060 n061

= 100 0

= 0 100

100%

FREQ

REF.

0%

0V

10V

INPUT VOLTAGE (TERM. FR)

FREQ. REF.
INPUT (V)

FREQ.
REF.
(%)

GAIN

110

100

90

10V

0V

100%

0%

(+)

()

GAIN

Advertising