Inverter – Mechanical and technical data

Model

6400xi

7600xi

Visual displays

LEDs: PV generator (green)

Grid-feed (green)
Fault (red)

LCD (2 x 16 characters)

LEDs: PV generator (green)

Grid-feed (green)
Fault (red)

LCD (2 x 16 characters)

Controls

2 keys for display operation and confi guration of parameters

DC cut-off point

Pre-installed and separable DC rotary disconnect switch

Connections

Screw compression terminals in the connection box

Cable connection via conduit fi ttings using 3/4” or 1/2” knockouts on

connection box Terminals accept AWG 4 to AWG 12, 75’C, copper

wire. Torque to 20lb-in (2.2N-m).

Interfaces

RS485, S0, error transmitting relay

Ambient temperature

–4 °F ... +140 °F (> 104 °F power derating)

Internal Temperature monitoring

> 167 °F temperature-dependent power limiting

> 185 °F disconnection from the grid

Max. humidity

95 % (not-condensing)

Cooling

Free convection (fan assist)

Protection class

NEMA-3R

Noise emission

<45 dB (fan operation)

Housing

Aluminium wall-mounted housing

Dimensions W x D x H

44

3/8

x 14 x 8

6/8

in.

44

3/8

x 14 x 8

6/8

in.

Weight

108 lbs

108 lbs