AC Wiring Confi gurations

The following table provides the different wiring confi gurations for installing and connecting the

AC conductors into and out of the inverter (refer to Figures 2-12 to 2-15 for installation drawings

showing these confi gurations).

Table 2-5, AC Input/Output Wiring Confi gurations

SI/SO (30A)

[Single In/

Single Out

(30A)]

SI/SO (60A)

[Single In/

Single Out

(60A)]

DI/SO

[Dual In/

Single Out]

DI/DO

[Dual In/

Dual Out]

AC Source

1

Required

120 VAC @ < 30

amps

120 VAC @

> 30 amps

(60 amps maximum)

120/240 VAC

(or two separate legs

of 120 VAC)

@ < 30 amps per leg

120/240 VAC

(or two separate legs

of 120 VAC)

@ < 30 amps per leg

Reason to

Use

Have a 120 VAC

source that is

< 30 amps.

Requires a

separate inverter

sub-panel

4

.

Have a 120 VAC

source that is > 30

amps.

Requires a

separate inverter

sub-panel.

Want dedicated

charging and

dedicated pass-thru

while the AC source

is on.

Requires a

separate inverter

sub-panel.

May need to power

240 VAC loads when

AC source is on

(requires 120/240

VAC source).

Requires a separate

inverter sub-panel.

Appropriate

MMP Models

MMP175-30D,

MMP250-30D

MMP175-60S,

MMP250-60S

MMP175-30D,

MMP250-30D

MMP175-30D,

MMP250-30D

Appropriate

Magnum

Inverter

Models

MS Series,

MS-AE Series,

MS-PAE Series,

RD Series

MSxx12, MS4024,

MS-AE Series,

MS-PAE Series,

RD Series

MSxx12,

MS4024,

RD Series

MSxx12, MS4024,

MS-AE Series,

MS-PAE Series,

RD Series

AC Input

Breaker

Provided

30A

(one pole of dual

pole breaker)

60A

(single pole)

30A

(dual pole)

30A

(dual pole)

Minimum AC

Wire Size

5

#10 AWG

(In & Out)

#6 AWG

(In & Out);

Can be split to two

#10 AWG

(for HOT 1

& HOT 2)

#10 AWG

(In & Out)

#10 AWG

(In & Out)

Maximum

Inverter

Pass-thru

Capacity

3600W

(30A @ 120 VAC)

5000W

2

(60A @ 120 VAC)

3600W

(30A @ 120 VAC)

5000W

2

(two legs of 30A

@ 120/240 VAC or

two legs of 30A @

120 VAC)

3

Wiring

Diagram

Figure 2-12

Figure 2-13

Figure 2-14

Figure 2-15

Note

1

– AC Source is from either the utility/grid power or an AC generator.

Note

2

– Enclosure capacity rated for 5000 Watts maximum.

Note

3

– If two legs of 30A @ 120 VAC are used, they must be from the same source.

Note

4

– The MS2012 and MS2000 models with integral branch circuit rated output breakers (i.e. MS2012-

20B) allows direct wiring from the unit to the load and do not require an inverter sub-panel.

Note

5

– Based on AC input breaker provided.