Operation

3.0 Operation

The MMP enclosure provides you with

circuit

breakers/disconnects to easily operate and maintain

your inverter/battery system. These breakers

are used as the main power disconnecting means

and/or overcurrent protection. Refer to Figure 3-1 (MMP F

unctional Diagram) to see the functional

operation of the breakers within the MMP enclosure.

Info: Figure 3-1 is for descriptive purposes only, for specifi c wiring directions please

refer to the relevant wiring diagram in the Installation section of this manual.

Info: For information on operating the inverter, refer to its owner’s manual.

If a short-circuit condition occurs, or if a load is placed on the circuit breaker that is more than its

rated capacity, the breaker will trip OFF (down). On the AC breakers, a red indicator will display

through the clear window on the circuit breaker to show a tripped condition. On the other circuit

breakers, the handle will trip all the way to the OFF position.
Before resetting the breaker, fi rst determine the cause of the overcurrent fault. Then, reset the

circuit breaker by turning it all the way OFF, and then all the way back ON. For proper maintenance

and longer life, the circuit breakers should be turned off and on several times at least once a year.

This will help to prevent the contacts inside from sticking together.
To shut the MMP/inverter system OFF completely, all of the circuit breakers in the MMP

enclosure should be switched to the OFF position.

Figure 3-1, MMP Functional Diagram

EXTERNAL AC Terminal Block

AC IN

AC OUT

AC

OUTPUT

AC

INPUT

INVERTER

(AC side)

INVERTER AC Terminal Block

INV IN

INV OUT

AC INPUT

Breakers

DC Side

AC Side

MMP Enclosure

AC

SOURCE

FROM MAIN

PANEL

(C

USTOMER

C

ONNECTION

)

DC

INPUT

INVERTER

(DC side)

DC Shunt

DC NEG Busbar

DC POS Busbar

INV DC Breaker

BATTERY

BANK

(Customer

Connection)

NEG (-)

POS (+)

AC BYPASS AC OUTPUT

ON

OFF

ON

OFF

DC

LOADS

(Customer

Connection)

DC

Breakers

(optional)

AC

LOADS

IN SUB-

PANEL

(C

USTOMER

C

ONNECTION

)