Appendix a - optional equipment and accessories – Magnum Energy Mini Magnum Panel (MMP Series) User Manual

Page 66

Advertising
background image

Page 57

©

2013 Magnum Energy, Inc.

Appendix A - Optional Equipment and Accessories

T

O

P

ROTECT

DC

INPUT TO

I

NVERTER

T

O

P

ROTECT

INPUT TO

DC

LOADS

T

O

P

ROTECT

AC

INPUT

TO

I

NVERTER

T

O

L

IGHTNING

A

RRESTOR

T

O

I

NVERTER

AC

INPUT

AC

TERMINAL

BLOCK

SIDE VIEW

N

OTE

: C

RIMP A RING

TERMINAL WITH A

5/16"

OPENING TO THE LIGHTNING
ARRESTOR WIRES AND
CONNECT TO THE

M

AGNUM

INVERTER

DC

TERMINALS

.

F

OLLOW THE PROPER

DC

HARDWARE STACK AND ENSURE
THERE IS NOTHING BETWEEN
THE

DC

BUSBARS AND THE

INVERTER

S

DC

TERMINALS

.

N

OTE

: T

HE

AC

TERMINAL BLOCK IS NOT RATED

TO CONNECT MORE THAN ONE WIRE LARGER THAN

#12 AWG. T

HEREFORE

,

TO CONNECT A

L

IGHTNING ARRESTOR

,

A SERVICE ENTRANCE

CONNECTOR

(

OR SPLIT BOLT

)

IS REQUIRED TO

CONNECT BOTH THE INVERTER

S

AC

INPUT WIRE

AND THE LIGHTNING ARRESTOR WIRE TO THE

AC

TERMINAL BLOCK

.

E

NSURE THE SERVICE ENTRANCE CONNECTORS ARE

INSULATED FROM EACH OTHER TO PREVENT THE

AC

INPUT WIRES FROM SHORTING TO EACH

OTHER

.

S

ERVICE

ENTRANCE

CONNECTOR

(

SPLIT BOLT

)

Lightning

Arrestor

(AC rated)

Lightning

Arrestor

(DC rated)

Lightning

Arrestor

(DC rated)

Figure A7-2, Wiring Lightning Arrestor to MMP Enclosure

Info: Make sure enough insulation is stripped so that the inverter’s AC input wire is

fully inserted in the AC terminal block and enough uninsulated wire is still available

to contact with the lightning arrestor wire when using the service entrance connector.
Info: Readily used service entrance connectors are available at most electrical dealers

– for example, the Type SX manufactured by Ilsco (

www.ilsco.com

), or the Type N

manufactured by Thomas and Betts (

www.tnb.com

).