Retrotec DucTester 200 Series Residential Applications User Manual

Page 5

Advertising
background image

Page 5 of 91
©Retrotec Inc. 2015

7.9

Save the Duct Leakage Test Report as a PDF file .................................................... 52

7.9.1.

With Office 2007: .................................................................................................. 52

7.9.2.

With Office 2010 ................................................................................................... 52

8.

Find air leaks in the ducts ........................................................................... 53

8.1

Using a smoke puffer ............................................................................................ 53

8.2

Using theatrical smoke ......................................................................................... 53

8.3

Using an infrared camera ...................................................................................... 53

8.4

Using a wet hand .................................................................................................. 53

8.5

Using a Pressure Pan............................................................................................. 53

9.

Measure the Air Handler system flow ........................................................ 55

9.1

For Code compliance ............................................................................................ 55

9.2

Why measure the Air Handler system flow? .......................................................... 55

9.3

Measure with a DucTester as a powered flow hood on the return ......................... 55

9.4

Measure with a DucTester on the air handler cabinet ........................................... 56

9.5

Measure with a gauge and a flow grid ................................................................... 56

9.6

Measure using air handler blower curves .............................................................. 57

9.7

Measure using Hole Flow on the gauge ................................................................. 57

9.8

Measure with a Blower Door attached to the return or cabinet ............................. 57

9.9

Other methods ..................................................................................................... 58

10.

Estimate HVAC system energy loss from ducts ........................................ 59

10.1

Duct Air Leakage Measurements ........................................................................... 59

10.2

Methodology ........................................................................................................ 59

11.

Field Check the DucTester to find out what is not working ...................... 63

11.1

Field Check the gauge ........................................................................................... 63

11.2

Field Check the tubes ............................................................................................ 63

11.3

Field Check the DucTester as a system .................................................................. 64

12.

Avoid common mistakes ......................................................................... 66

13.

Create a Blower Door with a DucTester fan ............................................. 67

13.1

Use a DucTester to test tight enclosures................................................................ 67

13.2

Blower Door System (tight enclosures) details ...................................................... 68

Appendix A: Calculate Air Flow based on Pressure readings ............................. 69

Appendix B: Flow Conversion Tables ................................................................ 71

Advertising