4.1.3. Anomalous cases during "AUTO", "R+TIMER", "R-TIMER" tests

)

CAL LOW

5.75

216

mA

5

s


AUTO

In case a value of Ravg or R+ or R-
greater than or equal to 5

but less

than 99.9

was detected, at the end of

the test the instrument emits a long
beep
and displays a screen similar to
the screen alongside.

Only in the case
R+TIMER or R-
TIMER was
selected.

ATTENTION: value of R

avg

greater than 5

AUTO mode.

)

CAL LOW

> 99.9

- - -

mA


AUTO

In AUTO mode, if a Ravg or R+ or R-
greater than 99.9

was detected, at

the end of the test the instrument emits
a long beep and displays the screen
alongside.

99.9

is the

maximum value
that can be
measured in the
LOW

AUTO or

R+ or R-mode.

ATTENTION: value of R

avg

or R+ or R- is too

high.

AUTO mode.

)

CAL LOW

> 99.9

- - -

mA

4

s

R+


TIMER

In the case mode R+TIMER or R-
TIMER was selected and a R+ or R-
greater than 99.9

Ω was detected, the

instrument emits an intermittent beep
during the test, a long beep at the
end of the test
and displays the screen
alongside.

99.9

is the

maximum value.

ATTENTION:
value of R+ or R-
is too high.

)

CAL LOW

ν 0.00

219

mA

AUTO

In case that:
R

MEASURED

-R

CALIBRATION

< 0

the

instrument displays the screen
alongside.

Blinking CAL.

ATTENTION: R

MEASURED

-R

CALIBRATION

< 0

AUTO mode.

SAVE

SAVING: