Save: "save" key, Pla 02 – Amprobe Multitest-1000 Continuity-Tester User Manual

Page 43

Advertising
background image

5. HOW TO SAVE, RECALL AND CLEAR DATA STORED IN MEMORY

5.1.

SAVE: "SAVE" KEY

If the results relative to the tests performed are to be stored you can proceed as follows:


1. Press

the

SAVE key once.

SAVE


)

MEM

3

PLA

02

If the memory of the instrument is not

empty it displays the screen alongside.

Number of the memory location in which the
measurement results will be stored.

Value of the parameter PLA related to the
measurement to be saved.



2. Use

the

& keys to increase or decrease the value of the PLA

(Place) parameter to be related to the measurement that is to be
saved. This parameter helps the operator to classify the tests
performed.

Example: If the tests are to be carried out in a building, the operator

can associate the measurements performed in a room
with a given value of the parameter PLA. In this way
different values of the parameter PLA will correspond to
different rooms.


3. Press

the

SAVE key again, the instrument emits two beeps,

confirming that the test results have been stored.

SAVE

RCL
ESC

Press RCL/ESC key at any time to leave the memory menu and go
back to the measurement selected.