29

Figure 8.9 Ceiling/Attic Construction

H. Complete Installation

WARNING! Risk of Fire! You MUST maintain 2 in.

(51 mm) air space to insulation and other combustible

materials around the chimney system. Failure to do so

could cause overheating and fire.

• Keep chimney sections from separating or twisting.

• You may secure straight chimney sections at the joints

with screws no longer than 1/2 in. (13 mm).

The following steps should be skipped if using a

chase.

• Install roof flashing appropriate to roof pitch.

• Install round termination cap and storm collar.

I. Install Flashing

• Assemble chimney so it passes through the framed

opening.

• Slip the flashing over the chimney.

NOTICE: Roofing shingles must be below the flashing

plate on the lower side of a sloped roof and over the

flashing plate on the sides and top.

• Nail the flashing to the roof. Keep gaps between the

flashing plate and the roof to a minimum.

• Caulk the flashing plate and roof junction as well as the

vertical seam on the flashing. All nail heads must be

caulked with a roofing sealant.

• Caulk the overlap seam of any exposed pipe sections

that are located above the roof line to prevent leaks

Heatilator • SC60 • 32838 • Rev AG • 7/12

G. Cut out Hole in Roof

• Refer to Figure 8.9.

• Plumb from roof to center of chimney.

• Drive a nail up through roof to mark center of pipe.

• Measure to either side of nail and mark the 14-1/2 in. x

14-1/2 in. (368 mm x 368 mm) opening required.

• Measure opening on the horizontal; actual length may

be larger depending on roof pitch.

• Cut out and frame opening.

• Refer to

Chapter 25 of the Uniform Building Code for

roof framing details.