B. install fireplace & chimney, C. install chase top – Heatiator Heatilator Wood Burning Fireplace SC60 User Manual

Page 32

Advertising
background image

32

Slope Downward

(1/4 in. per foot

minimum)

Turn-down

Drip Edge

Chase

2 in. (51 mm) Collar

on Chase Top

.018 (26 ga) min.

Galvanized

Chase Top

Figure 9.3 Chase Top Construction

B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

Heatilator • SC60 • 32838 • Rev AG • 7/12

C. Install Chase Top

• You MUST use a chase top in a chase installation. Chase

tops are available from your Heatilator dealer or may be

field constructed.

• Include a turndown and drip edge to prevent water from

seeping into the chase.

• Include a 2 in. (51 mm) soldered, welded or spun collar

around pipe opening to keep water out.

• Provide a 1/8 in. (3 mm) gap around the flue pipe.

• Slope the chase top downward away from the

opening.

WARNING! Risk of Fire! DO NOT caulk the pipe to the

chase top collar.

• Caulk all seams to prevent leaks.

• Refer to Figure 9.3.