7Ć2 Calibrations

C3187Ć90000

When toCalibrate the Plotter

Indications or Repairs Performed

Calibration Required

Jagged lines on plots

Cartridge Alignment

Cartridges are reseated or replaced

Cartridge Alignment

Drive roller is removed or replaced

Accuracy Calibration

Media (X-axis) motor is replaced

Accuracy Calibration

Configuration-plot X-mark distance is not
500mm (

"

1mm)

Accuracy Calibration

Carriage or carriage LED is removed or replaced

Cartridge Alignment
and Setup-Sheet Calibration

Edge-detect failures occur

Cartridge Alignment

Bail failures occur during media loading

Bail Calibration

Bail sensor is removed or replaced

Bail Calibration

Bail-lift mechanism is removed or replaced

Bail Calibration

Media sensor is removed or replaced

Media-Sensor Calibration

Leading and trailing margins of a plot are greater
than 17 mm (0.67 in)

Media-Sensor Calibration

Problems occur scanning a setup sheet.

Setup-Sheet Calibration

EEROM is cleared or main PCA is replaced

(In this order:)
1. Bail Calibration
2. Media-Sensor Calibration
3. Cartridge Alignment
4. Accuracy Calibration
5. Setup-Sheet Calibration

Service Mode

DnUeS:nN FeSW:Ge ERde

, Switch the plotter off.
. While holding the

Align Cartridges

key down,

switch the plotter on.

A Once the

Busy

LED lights up, release the

Align Cartridges

key.

T

z

z

H z

!

H d

H

H

H H

T

z

d

Di it Ji 220 pl

i b

Draft, Final, Paper

H d

Transl/Vellum

H

d P

H

H d

z H

Advertising
This manual is related to the following products:

200