Aligning the cartridges – HP 220 User Manual

Page 48

Advertising
background image

5Ć16 Functional Overview

C3187Ć90000

Aligning the Cartridges

The cartridgeĆalignment system is composed of

D Stepper motor
D Adjustment linkage
D Adjustment cam
D Adjustable cartridge chute
D Carriage drive

(Illustrations ' pages 10Ć15 and 10Ć21.)

Operation
The following operation is used to align one cartridge with respect to the other in the XĆaxis

(media axis). (YĆaxis and ZĆaxis realignments are done by varying the firing timing of each

nozzle resistor.)

1 The stepper motor presses up on the lower link of the three adjustmentĆlinkage pieces by

means of the plastic actuator pressed onto the motor shaft.

2 This action lowers the top link of the adjustment linkage.
3 The carriage moves, and the adjustment cam, which comes into contact with the top link,

is rotated.

4 The cam action causes the adjustable cartridge chute to move in either the plus or minus

XĆaxis direction relative to the fixed cartridge chute.

(Instructions ' chapter 7, w Cartridge Alignment.)

Advertising
This manual is related to the following products:

200